Home > Technology
  Electrolytic Water Jet Deflash System
    - Inlined Water Jet Deflashing System with Electrolytic Deflasher as pretreatment process.
    - Footprint : 4000mm (L) x 1620mm (W) x 1600 (H)
    - Applied Packages : SOT-23 & Family, TO-220 & Family, QFP, PLCC, DIP, QFN, MLF, Etc.

  Onloading & Offloading Section
    - Automatic 'Pick and Place' , Mag. To Mag.
    - Various optional application by Customers' requirements
  Electrolytic Deflashing Section
    - Alkaline Electrolysis Deflash Solution like ED-300
    - Principle
   
  Cathodically Polarized : Anode + Cathode
  Hydrogen Gas Generation by Electrolysis Reaction
  Strong Micro-Circulation on L/F surface
  Getting Mold Flash/dirties loose from the L/F surface

  Rinsing Section
    - City Water Rinse

  Water Jet Deflashing Section
    - Water Jet Blasting Area : Both Areas of L/F
    - Shock Absoring Support Roller
    - Nozzle Quantity : Depends on product type (Generally 8-12 nozzles)
  Drying Section
    - Compressed Air Dryer
    - Hot Air Dryer

  Control Section
    - PLC Controller with LCD Touch Screen
    - Working parameters and self-diagnostic errors LCD display
  Strip Conveying Section
    - Endless Gripper Belt Conveyor
    - Variable Belt Speed upto 6m/min
    - Spring Gripper with easy mounting/demounting on belt